hero-mediacenter

Media Center

Back to Media Center
pp-577-0487-test report

An Evaluation of Particle Shedding from a New Levitronix® BPS-3 Pump During the Initial Flush with Ultrapure Water

Keywords:
  • Initial Flush
  • Microelectronics
  • Particle Shedding
  • Pump
View document

Facts
The flush of a new pump system leads to a clean-up of initial particle contamination. The clean-up quality of a pump system is characterized by the flush-up volume needed to reduce the particle levels.

Test Conditions
A Levitronix® BPS-3 pump was evaluated for particle shedding during the initial flush. The pump was connected to a source of UPW and flushed for 48 hours. The particle concentration downstream of the pump was measured.

Results
After being flushed with 420 liters of water, the pump was adding less than 0.1 particle/ml. The clean-up quality of this pump was excellent.

Cumulative particle concentration of different particle sizes during the flush of a BPS-3 pump

Author Dennis Chilcote
Company CT Associates
Document Number PP 577 0487
Pages 3